IVIS Lumina II is 2D optical imaging system, both for
live cell and live animal imaging in Bioluminescence,
Fluorescence and Cherenkov luminescence mode.
It allows scanning of upto 3 mice at a time.
Equipped with four standard fluorescence emission filters GFP, Cy5.5, DsRed and ICG.
| Imaging System Components | Specifications | | Camera Sensor | Back-thinned, back-illuminated CCD |
| CCD Operating Temperature | -90 °C |
| Min.-Max. Field of View (FOV) | A to D (5 cm- 12.5 cm) |
| Camera Lens Aperture (F/Stop) | f/1 – f/8 (1.5x, 2.5x, 5x, 8.7x magnifications) |
| Min. Image Pixel Resolution | 50 microns |
| Excitation Fluorescence Filters
Emission Fluorescence Filters | 10 (Min. 430 nm, Max. 745 nm with ± 35 nm bandwidth). |
| Illumination source | Epi-illumination |
| Imaging Chamber | Heated Imaging Stage: 37 °C
Integrated gas anaesthesia |

IVIS spectrum is used for both live cell and live
animal imaging in Bioluminescence, Cerenkov
luminescence and NIR fluorescence mode.
Allow scanning of minimum one to maximum five
mice per scan in 2D planar mode and 1 mouse for
3D tomographic imaging mode
Spectral unmixing imaging capacity of IVIS
Spectrum provides scope of using multiple probes
emitting non-overlapping photonic signatures.
Uses Structured Light Image to reconstruct the
surface tomography of the subject for DLIT and
FLIT algorithm.
Uses transillumination setup to enable effective
excitation of deep tissue signal in FLIT mode.
| Imaging System Components | Specifications | | Camera Sensor | Back-thinned, back-illuminated CCD |
| CCD Operating Temperature | -90 °C |
| Min.-Max. Field of View (FOV) | A to D (4 cm-22.4 cm) |
| Camera Lens Aperture (F/Stop) | f/1 – f/8 (1.5x, 2.5x, 5x, 8.7x magnifications) |
| Min. Image Pixel Resolution | 20 microns |
| Excitation Fluorescence Filters | 10 (Min. 430 nm, Max. 745 nm with ± 35 nm bandwidth) |
| Emission Fluorescence Filters | 18 (Min. 500 nm, Max. 840 nm with ± 20 nm bandwidth) |
| Illumination source | Epi-illumination Trans-illumination |
| Imaging Chamber | Heated Imaging Stage: 37 °C Integrated gas anaesthesia |

The IVIS Spectrum-CT is a powerful platform for small
animal imaging in pre-clinical settings.
It provides key optical imaging functionalities:
Bioluminescence (BLI), Fluorescence (FLI) and
Cerenkov luminescence, for both live cell and live
animal imaging.
High throughput system which allow upto 5 mice in
2D planar scanning mode and upto 2 mouse for 3D
scanning mode
This system provides full 3D tomographic imaging
support with co-registered optical signals with precise
anatomical (CT) images for volumetric reconstruction of
molecular signals.
Operate in a board spectral range, from visible to near
infrared (NIR) light. Spectral unmixing imaging capacity
provides scope of using multiple probes emitting non-
overlapping photonic signatures.
| Imaging System Components | Specifications | | Camera Sensor | Back-thinned, back-illuminated CCD |
| CCD Operating Temperature | -90 °C |
| Min.-Max. Field of View (FOV) | A to D (4 cm-22.4 cm) |
| Camera Lens Aperture (F/Stop) | f/1 – f/8 (1.5x, 2.5x, 5x, 8.7x magnifications) |
| Min. Image Pixel Resolution | 20 microns |
| Excitation Fluorescence Filters | 10 (Min. 430 nm, Max. 745 nm with ± 35 nm bandwidth) |
| Emission Fluorescence Filters | 18 (Min. 500 nm, Max. 840 nm with ± 20 nm bandwidth) |
| Illumination source | Epi-illumination Trans-illumination |
| Imaging Chamber | Heated Imaging Stage: 37 °C Integrated gas anaesthesia |
| X-ray Detector Type for Computed Tomography | CMOS (Complementary Metal-Oxide-Semiconductor) |
| Detector Size | 3072 x 864 pixels |
| Standard Scan Dose | Minimum of ~13 mGy |